Filter Results By:

Products

Applications

Manufacturers

Integrated Circuit

Passive or active components test and their interconnected circuitry in silicon or germanium.

See Also: IC, Chip


Showing results: 196 - 202 of 202 items found.

  • High-Density Precision SMU (10 PA, 30 V)

    PZ2131A - Keysight Technologies

    The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.

  • Analog Power Supply

    Type NPS-2412 - National RF, Inc

    National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.

  • Radiation Microdosimeters

    Teledyne Defense Electronics

    Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.

  • RF Power Amplifiers

    Pasternack Enterprises, Inc.

    RF power amplifier category from Pasternack have components packaged in a hermetically-sealed metal enclosures and exhibit outstanding performance in high gain, gain flatness, high linearity and wide dynamic range. RF power amplifiers have excellent performance by using a hybrid microwave integrated circuit design and advanced GaAs pHEMT components. These SMA power amplifier modules are unconditionally stable and include built-in voltage regulation, bias sequencing, and reverse bias protection for added reliability.RF power amplifier over-voltage protection is installed externally for easy repair. These high reliability radio frequency power amps are fully matched internally for 50 Ohm input and output. This 50 Ohm power amplifier matching helps eliminates the need for any additional sensitive external RF tuning components.Our power amps are ideally suited for high linearity applications. These radio frequency power amplifiers offer small signal gain over a temperature range. The Pasternack RF power amplifiers have excellent gain flatness ranges and the IP3 output performance.Most all Pasternack RF power amplifiers are EAR99

  • High Voltage 50 Ω Pulse Generator

    TLP-12010A - High Power Pulse Instruments GmbH

    - High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external pulse width extensions from 5 ns to 500 ns using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient software for system control and waveform data management- The software can control automatic probers for fast measurements of complete wafers- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface

  • 120 A High Voltage 50 Ω Pulse Generator

    TLP-12010C - High Power Pulse Instruments GmbH

    - High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface

  • Leeb Hardness Tester

    THL500 - TMTeck Manufacturing Limited

    It is the highest brightness display in China showing all functions and parameters, easy read Largest screen Oled screen and operate,also can save lots of energy .the largest screen of Leeb hardness tester in China. Two hardness scale dual-display in the screen. Measuring direction in 360 and add the auto measure direction to make test easy and precision. Add four new hardness scales, HRA, HB for D impact device of alloy tool steel; HV for cast aluminum alloy. Add New user material function, to meet the need of user can test the special material. Test at any angle, even upside down. Wide measuring range. It can measure the hardness of all metallic materials. Direct display of hardness scales HRB, HRC, HV, HB, HS, HL and three types of strength values immediately. Seven impact devices are available for special application. Automatically identify the type of impact devices. Large capacity memory could store 600 groups (Relative to average times321 ) information including single measured value, mean value, testing data, impact direction, impact times, material and hardness scale etc. Upper and lower limit can be preset. It will alarm automatically when the result value exceeding the limit. Battery information indicates the rest capacity of the battery and the charge status. User calibration function. USB port with the PC humanity multi-functions data proceeding software. Original imported high speed thermal printer support the immediate printing function. It can save data permanently. Li rechargeable battery as the power source. Charge circuit integrated inside the instrument. Continuous working period of no less than 200 hours (EL off and no printing). Auto power off to save energy. Excellent after-sale service system for high quality products---3 years guarantee and all life maintenance. Easy to buy and comfortable to use.

Get Help